CEMS

Process Engineering Services, Inc.

Choose Our Custom Monitoring System

Contact Us

Do You Require a Continuous Emissions Monitoring System (CEMS)?

The majority of carbon adsorption systems are equipped with an emissions monitoring system that determines carbon bed breakthrough or the saturation of the carbon beds. CEMS also help maintain environmental compliance by limiting emissions to the atmosphere.

At Process Engineering Services, we have our own design of FID (Flame Ionization Detector) monitoring systems (105 FID CEMS) that one designed and manufactured by us. Dozens of these systems are in operation all over the world, some for more than 20 years.

We also service competitors FID CEMS.

Full Specifications of Model No. 105 Monitoring System

  • This fully pre-engineered, modular-designed and free-standing equipment is equipped with a Hydrocarbon analyzer, a recorder and a calibration facility:
    • Rosemount 400A Total Hydrocarbon Analyzer (has 7 selectable ranges from 0-1 PPM to 0-30,000 PPM full scale, with valving for manual inlet sampling for on-demand real-time measurement of adsorber efficiency)
    • Flame Ionization Detector / Analyzer (to determine the total gaseous organic concentration, in compliance with the EPA method 25A as stated in the federal regulations)
    • Honeywell DR 4300 Single Pen Circular Chart Recorder (with internal relays for on / off control and alarms, internal sample pump and calibration facilities)
  • It includes the following:
    • All calibration valving and tubing
    • All interconnected tubing and wiring between the absorber and monitoring system
    • Compressed gas bottle stand with chains
    • Cabinet with rack-mounted monitor, recorder and all valving mounted in it
    • All electrical / mechanical switch-over controls required to install the monitoring system to adsorption system (solenoid sampling valves, filters, timers, etc.)
    • 25-day supply of chart papers and pens for the recorder
  • Compressed gases required (our price doesn't include regulators and gases):
    • Hydrogen / Nitrogen mix (fuel)
    • Methane in air (calibration gas)
    • Breathing quality air (combustion air) < 1 PPM THC
  • Physical characteristics:
    • Model 105 monitoring system cabinet - 58" H x 22" W x 25 1/2" D
    • Gas bottle rack - 54" H x 48" W x 12" D
    • Weight is approximately 300 lbs.

The complete model 105 monitoring system is priced at $19,750 FOB E. Freetown, MA.

  • Some available options that are priced separately include:
    • Installation / start-up
    • Ongoing service programs
    • Onsite training programs
  • Our customized maintenance programs include:
    • Multichannel, paperless, digital data recorders
    • Multi-tank sampling system
    • Manual inlet sampling for on-demand real-time measurement of overall adsorber efficiency (now standard on all models)
    • Automatic inlet sampling for continuous adsorber efficiency and data collection
    • Stainless steel tubing systems for corrosive gaseous sampling